| UpanelII0.9 | UpanelII1.05 | UpanelII1.12 | UpanelII1.19 | UpanelII1.2 | UpanelII1.5 | Current model UpanelII1.9 | UpanelII2.5 | |
|---|---|---|---|---|---|---|---|---|
| Pixel pitch? | 0.95 | 1.06 | 1.12 | 1.19 | 1.2 | 1.59 | 1.91 | 2.54 |
| Brightness? | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 |
| Hz? | 3840 | 3840 | 3840 | 3840 | 3840 | 3840 | 3840 | 3840 |
| Cabinet material? | Die-casting aluminum | Die-casting aluminum | Die-casting aluminum | Die-casting aluminum | Die-casting aluminum | Die-casting aluminum | Die-casting aluminum | Die-casting aluminum |
| Viewing angle horizontal? | 160 | 160 | 160 | 160 | 160 | 160 | 160 | 160 |
| Viewing angle vertical? | 160 | 160 | 160 | 160 | 160 | 160 | 160 | 160 |
| Type | outdoor-indoor | outdoor-indoor | outdoor-indoor | outdoor-indoor | outdoor-indoor | outdoor-indoor | outdoor-indoor | outdoor-indoor |
| Pixel pitch front | 0.953 | 1.058 | 1.12 | 1.19 | 1.2 | 1.5883 | 1.906 | 2.54 |
| Pixel pitch back | 0.953 | 1.058 | 1.12 | 1.19 | 1.2 | 1.5883 | 1.906 | 2.54 |
| Cabinet width | 609.92 | 609.92 | 609.92 | 609.92 | 609.92 | 609.92 | 609.92 | 609.92 |
| Cabinet height | 343.08 | 343.08 | 343.08 | 343.08 | 343.08 | 343.08 | 343.08 | 343.08 |
| Cabinet thickness | 68 | 68 | 68 | 68 | 68 | 68 | 68 | 68 |
| Cabinet weight | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 |
| Average power | 48 | 48 | 48 | 48 | 43 | 43 | 43 | 26 |
| Maximum power | 145 | 145 | 145 | 145 | 130 | 130 | 130 | 80 |
| Cabinet service | Front | Front | Front | Front | Front | Front | Front | Front |
| Pixel pitch? | 1.91 |
| Brightness? | 600 |
| Hz? | 3840 |
| Cabinet material? | Die-casting aluminum |
| Viewing angle horizontal? | 160 |
| Viewing angle vertical? | 160 |
| Type | outdoor-indoor |
| Pixel pitch front | 1.906 |
| Pixel pitch back | 1.906 |
| Cabinet width | 609.92 |
| Cabinet height | 343.08 |
| Cabinet thickness | 68 |
| Cabinet weight | 7 |
| Average power | 43 |
| Maximum power | 130 |
| Cabinet service | Front |
Интеллектуальный режим MDC — реализуйте быстрый переход к различным режимам сцены (опционально).
Защита U-shield — эффективное рассеивание тепла и высокая степень защиты IP60.
Фронтальное обслуживание.
Беспроводное соединение между шкафами - продлевает срок службы экрана.
Применяя герметичную структуру и новый модульный дизайн, UpanelII обеспечивает эффективное рассеивание тепла и высокую степень защиты IP60.
Бескабельная конструкция между шкафами не только эффективно снижает частоту отказов, но и продлевает срок службы экрана.
Выключатель питания шкафа имеет телескопическую конструкцию для обеспечения 100% безопасной работы.
Модули, блоки питания и внутренние кабели можно заменять спереди. Конструкция полного переднего обслуживания не только экономит время, но и снижает затраты.